Yes and no. If it is a small building and all the emergency lights are on one circuit, then yes, you have no choice. However if it is a large building then it would make sense to stagger the testing. This way the whole building would not be affected if there was a power cut, during the recharge time. Testing Central Battery Systems Details of any repairs or replacements carried out on the emergency lighting system, including dates and the nature of the work carried out. After this full discharge test, precautions must be taken as the batteries can take up to 24 hours to recharge and so the premises should not be occupied until everything is restored. For many buildings it is possible to do this over the weekend, but for flats and other premises which are occupied full time, there will need to be other arrangements whilst the batteries are recharging. Be very careful when touching anything inside the electrical consumer box, there is a danger of electrocution if something is wrong. If in doubt seek a qualified electrician ** What time of day should I test the emergency lights As I understand it the EL light units that (should) have LEDs on them, the LEDs are illuminated when in normal 'charging' mode but go out when in EL mode?

An Emergency Lighting Certificate is a document that certifies that the emergency lighting system in a building has been installed, tested and commissioned in accordance with the relevant regulations and standards. The certificate is issued by a qualified electrician or contractor who has carried out the installation and testing of the emergency lighting system. In my humble opinion the switch should be of "simulation" status IE cutting power (as it would if in a power cut, fire, etc.) and illuminating EL only. The kind of emergency lighting system your building requires depends on the nature of your business. For example, the emergency lighting system is not always required to provide light at the same intensity as the mains (however, it should be bright enough for safe evacuation). By working with the qualified engineers at Voltix Services , system designs and the ideal testing regime are all part of our compliance services . Non-domestic properties have a statutory responsibility to supply, test, and maintain emergency lighting systems. The reason for the regulations is to promote safety should the power supply go down for any reason. In such an event, emergency lighting provides illumination for safe evacuation or manoeuvre around the building’s interior. It can also support operational continuity in some contexts.L SW is the normal mains supply. A normal light switch, or sensor, would usually be on this circuit to enable the end-user to have control over the light fitting in normal operating mode. L SW is always to be wired so that any switching of L PERM will disconnect L SW too, but any switching of L SW will not affect L PERM. They can also provide insights on the suitability of systems in respect of applicable British standards and codes. Confirmation that the emergency lighting system has been installed in accordance with the relevant regulations and standards.

An emergency log book is required to keep a record of all the testing, maintenance, and servicing carried out on an emergency lighting system. It is a legal requirement to keep an emergency log book for each building that has an emergency lighting system installed. Records of all testing and maintenance carried out on the emergency lighting system, including dates, results, and any faults or issues identified. Now the refurbishment on the ground floor seems to be wired up in the 'new' way - does not extinguish power to mains. Is your building permanently used E.G. Hotels, then you need to test the lights so that the end of the test corresponds to the start of day. In this way the emergency lights will have a good time to recharge during daylight hours. Natural daylight will help if the emergency lights don’t last 3 hours. Should I test ALL emergency lights at once? Self-test has several benefits. First, it saves the labour of manual testing. Secondly, it removes the risk that routine monthly or annual testing is overlooked.

Technical Support

Sometimes there isn’t a test key switch. If not then you have to find the consumer unit and turn off the power to the whole circuit that controls the emergency lights. Hopefully it will be marked which one it is, but it could be more than one circuit. BS5266-1 states that emergency lighting should be regularly tested. How often should emergency lighting be tested? There are different ways to test emergency lighting in the UK, depending on the type of emergency lighting system and the requirements of the relevant regulations and standards. However, the following is a general procedure for testing emergency lighting: Test facilities often take the form of a fishtail key inserted into a specific switch, either near the main fuse board or relevant light switches. Additional Combined Services

The duration that emergency lighting should stay on for depends on the relevant regulations and standards, as well as the specific requirements of the building and its occupants. However, the general requirement is that emergency lighting should remain illuminated for a minimum of 1 hour, but it may need to remain illuminated for up to 3 hours in certain circumstances. Yes if you are testing/servicing on the discharge test then no lights would be a problem for persons working in those areas and so this would need doing when unoccupied - so I can see the logic behind the key switches not shutting off power - but that would only be for green LEDs and not red LEDs that would be difficult to visually see - similar if 3 tube lighting is working and one of the tubes is the EL light you wouldn't know if that EL unit was working if the main lights are still being powered...It can take up to 24 hours for batteries on emergency lighting systems to recharge after a full discharge test. For businesses, testing should be planned around periods of non-occupancy – like over the weekend. In full-time tenanted buildings, other strategies may be necessary to ensure that systems work around testing times. It is worth noting that the duration of emergency lighting may vary depending on the specific application. For example, in areas where there is a higher risk to the safety of occupants, such as escape routes, the emergency lighting may need to remain illuminated for a longer period of time. This should be determined through a risk assessment and in accordance with the relevant regulations and standards. UK fire safety legislation states that emergency lighting is required in buildings to provide light if normal lighting fails during a fire. Confirmation that the emergency lighting system has been designed and installed to meet the specific requirements of the building and its occupants.