Megger TPT420 LCD/LED Two-Pole Voltage Tester

£29.995£59.99Clearance
ZTS2023's avatar
Shared by
ZTS2023
Joined in 2023
82
63

About this deal

On older style CCVTs, the potential terminal is typically accessible. However, for modern CCVTs such as those supplied by Trench, the potential terminal is inaccessible. Even in these cases, however, C2 can still be tested. CCVTs have a potential ground switch that provides the means to ground the potential terminal. With the potential ground switch closed, the carrier terminal can be energised, a low voltage lead connected to the line terminal (top of C1), and a C2 test performed in the GST-guard mode. Note that the carrier terminal must be disconnected and isolated from ground potential and the drain coil (also, if applicable, from any accessory leads) for the C2 test. In addition, the test voltage (typically 500 V) used to energise the carrier terminal must not exceed the voltage rating of the terminal. In summary:

Validation of insulation, ratio and burden at rated voltage requires large and heavy test equipment used in conjunction with expensive instrumentation. For this reason, these tests are commonly used during the manufacture of CCVTs but are impractical in the field. Nevertheless, field measurements of the CCVT burden, as an aid to ensuring that the burden rating of the device is not exceeded, are possible. At its core, a voltage tester is a simple device designed to indicate the presence of electrical voltage in a system or a component. The underlying principle lies in Ohm's Law. This states that the current passing through a conductor between two points is directly proportional to the voltage across the two points. Figure 1 provides examples of surge traces for a good winding and a winding that has weak insulation or a turn-to-turn short. The three traces – corresponding to the three phases of the motor’s windings – should overlay as one on the graph but, as can be seen, the trace for a winding with a turn-to-turn short is different from the traces for the other two phases. Works below the tipping thresholds of RCDs, RCBOs and safety breakers when testing circuits between phase and earth As mentioned in the previous article, there are many options for testing insulation, and Megger supplies an extensive range of testers for such applications, from 50 V to 15 kV insulation testers, through VLF and AC Tan Delta test sets to diagnostic Dielectric Frequency Response instruments and, under the Baker brand, specialist motor testing equipment up to 40 kV.Go/no-go tests are an invaluable part of every maintenance regimen. Options include insulation resistance, leakage current, polarisation index and step voltage testing, and there are few who would argue against the benefits of these core electrical tests. However, these tests will not reveal one of the most common early initiators omotor faults: inter-turn insulation breakdown. To detect such a breakdown, it is necessary to use a surge test. Unfortunately, this is the area where some confusion has been generated in relation to the ‘high’ voltages involved.

When the probes of a voltage tester are connected to two points in an electrical circuit (commonly one end to a suspected live conductor and the other to a ground source), a closed circuit or loop is formed. This allows electrical current to flow from the higher potential to the lower potential. When testing between phase and earth on any circuit protected by an RCD, RCBO, and Safety Breaker, the TPT420 is designed to work below the tripping threshold of these devices to help avoid unintentional disconnection. The phase rotation indication test has been simplified, which now avoids the crossing of the test probes. The TPT420 can also perform a single-pole voltage indication test.And it’s the same with a surge test generated by a Baker DX tester. It applies a voltage and rise-time to enable you to see the inter-coil response, but with a signal controlled in voltage, time and energy, so that the impact on the motor is similar to the spikes that the motor receives as a result of typical power-system variations during everyday operation. In addition to the unit's adaptable auto-ranging voltage and continuity tests, the Megger MET1000 has a built-in current clamp for AC current measurement to 200 A. With true RMS AC measurements, a phase rotation test, and single pole voltage test built in, the MET1000 is a truly multi-purposeelectrical test instrument, ideal for use in commercial, industrial, and domestic environments. It even comes with GS38 shrouds, provided as standard, to ensure compliance with the latest standards.

Asda Great Deal

Free UK shipping. 15 day free returns.
Community Updates
*So you can easily identify outgoing links on our site, we've marked them with an "*" symbol. Links on our site are monetised, but this never affects which deals get posted. Find more info in our FAQs and About Us page.
New Comment