The government has introduced a ‘full fabric specification’ for setting the level of the Fabric Energy Efficiency Standard (FEES). This means a tightening of U-values. If the same builder has produced an identical construction in the last 12 months and successfully passed an airtightness test Improvements are also required in lighting efficiency but perhaps the biggest challenge is the new low flow temperatures for heating systems. The maximum flow temperatures in a central heating system is now 55°C where it was previously over 75°C. Mark Siddall, principal architect and director of research at the Lovely Engineered Architectural Practice (LEAP), says: “I think the updates could go a lot further. We should be aspiring towards better performing buildings, and the Building Regs are tailored towards the lowest common denominator. There could be more ambitious fabric standards and overall performance, which would cut people’s bills, improve their comfort and also reduce carbon emissions.” Friends of Newlands Spring (FONS) is our parents’ association which works tirelessly to raise funds for the school through a variety of fayres, discos and other events through the year.

The new rules require a 30% reduction in carbon when compared to 2013 Part L standards, which may seem quite high, but they are rather insignificant when compared with the 75–80% reduction in carbon which will be required by the Future Homes Standard. Appropriate conduct and language are expected of all examinees participating in NEWL. Any use of inappropriate language on any section of the exam will invalidate the entire exam and no score report will be issued. Inappropriate language includes offensive language or topics in either the speaking or writing section of the exam. We are a member of Attain Academy Partnership andthe lead school in the Chelmsford Teaching SchoolAlliance (CTSA). Mandatory water treatment for every heating system, is now recognised by reference to BS 7593: 2019. This outlines the best practices for the preparation of the primary wet central heating systems. Each system should be designed to allow for efficient cleaning and flushing and addition of water treatment chemicals. Good practice during installation should limit the ingress of installation debris such as millscale, metal swarf, soldering flux, jointing compounds and grease.

Students can choose to take the examination on either school-provided computers or their own computers. All computers, whether provided by the school or owned by students, must be configured during the lab setup week between April 8-12, 2024. The planned carbon reductions can mainly be achieved through the implementation of renewable technologies such as solar PV panels and heat pumps.

The uplift will also encourage the installation of air source heat pumps and ground source heat pumps.

Modification and Termination

Construction begins; any changes from specification should be notified to the SAP assessor during the build to ensure it still remains compliant

For new builds, SAP calculations are made at the design stage to arrive at a Predicted Energy Assessment (PEA). This provides a rating of energy performance based on the design of the house and shows the building inspector that the home will meet the requirements under Building Regulations Part L.Publication of 2018 editions of Approved Document L1B and Domestic Building Services Compliance Guide incorporating 2018 amendments. Bottom line: the 85L only advantage compared to every other 85 1,4 on the market (or even 85 1.8 like the FE 85 1.8 with T=1.8) is additional blur at 1.2. The ‘Boiler Plus’ requirements were set out in 2018 and remain the same. These requirements state that a gas combination boiler (whether this being installed in a new or existing system) must include one of the following:

Primary Admissions Offer (Video): We are looking forward to welcoming our new Foundation Stage children in September. If you were not successful in gaining a place at a school of your choice, Essex County Council has made this video to help with any questions: https://www.youtube.com/watch?v=U9nnRicMHOk&feature=youtu.be. An installer will need to calculate heat loss for all heating system types, including oil, gas and renewable systems. Self builders will be encouraged to meet ‘notional’ dwelling targets for energy efficiency. These are measured in U-values (the amount of energy that is lost through any material): if you can meet the reference targets for elements and systems including party walls, floors, doors and roofs then your home will result in a pass with building control.

But truth is that every comparison show little difference of DOF blur between 1.2 and 1.8 and 1.2 in a lot of case on FF is impractical, even for portrait, due to the too thin DOF. Indeed, if this lens at a T-stop of 1,5 or 1,6 as have Canon f1.4 modern lenses, it will be already as fast as the 85L. The IS will give 4 stops more which is huge advantage because you can easily shot portrait of static subject at 1/20 or even 1/10s whereas the L does not allow that. High efficiency condensing gas boilers will meet the minimum requirements for Part L, but only when combined with secondary energy efficiency levels such as: